Trotec Pyrometer TP7 Infrared Thermometer
Trotec Pyrometer TP7 Infrared Thermometer
- Development, design, production: 100 % Trotec
- Non-contact surface temperature measurement from -50 °C to +1,000 °C
- Measuring optic 30:1
- Measuring spot diameter display due to dual laser technology
FIND YOUR TROTEC STOCKIST HERE:
The universal infrared thermometer for many fields of application
Impressive technical performance data, e.g. a temperature measuring range from -50 °C to +1,000 °C, a high optical resolution of 30:1 or the innovative dual laser combined with a remarkable price-performance-ratio, make the TP7 a universal professional infrared thermometer for manifold fields of application.
The TP7 enables the material-specific adjustment of the degree of emission and comes equipped with a brilliant, backlit display for fatigue-proof reading of measured values even in poorly illuminated environments.
Moreover, the TP7 impresses with numerous professional equipment features, e.g. alarm function with freely definable limit values, non-stop measuring mode and functions to hold the current measured value as well as for the determination and display of the maximum value.
Particularly convenient application offers the innovative dual laser of the TP7, which automatically visualizes the size of the measuring spot. The distance between both laser beams corresponds to the measuring spot’s diameter.
Owing to the high temperature measuring range and the non-contact measurement principle, the robust TP7 is ideally suited for temperature measurements at poorly accessible, hot, movable or dangerous measuring points.
Thanks to the improved optics, even smaller objects can be measured from further away.
Despite its professional equipment, the compact TP7 was uncompromisingly designed for operator convenience and is ready for immediate use:
Simply aim, trigger and read the surface temperature on the backlit display.
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.003.012 | |
Optics | ||
Optical resolution (D:S) | 40:1 | |
Smallest measuring spot | 25.4 mm | |
Infrared temperature sensor [°C] | ||
Min. measuring range | Infrared temperature sensor [°C] | -50 | |
Max. measuring range | Infrared temperature sensor [°C] | 1,000 | |
Max. accuracy [°C] | Infrared temperature sensor | ||
Accuracy < -4°C | ||
Accuracy -4°C to 65 °C | ||
Accuracy > 65 °C | ||
Accuracy < 20 °C | ||
Accuracy = 20 °C | ||
Accuracy -50 °C to 20 °C (-58 °F to 68 °F) | ± 2.5 | |
Accuracy 21 °C to 300 °C | ± 1 | |
Accuracy 301 °C to 1,000 °C | ± 1.5 | |
Accuracy 21 °C to 400 °C | ||
Accuracy 401 °C to 800 °C | ||
Accuracy 800 °C to 1,600 °C | ||
Repeatability -50 °C to 20 °C | ± 1.3 | |
Repeatability 21 °C to 1,000 °C | ± 0.8 / ± 0.5 | |
Repeatability 21 °C to 1,200 °C | ||
Repeatability 1,201 °C to 1,600 °C | ||
Accuracy 20 °C to 500 °C (68 °F to 932 °F) | ||
Accuracy 500 °C to 1,000 °C (932 °F to 1,832 °F) | ||
Accuracy 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) | ||
Repeatability 20 °C to 1,000 °C (68 °F to 1,832 °F) | ||
Repeatability 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) | ||
Infrared temperature sensor [°F] | ||
Min. measuring range | Infrared temperature sensor [°F] | -58 | |
Max. measuring range | Infrared temperature sensor [°F] | 1,832 | |
Accuracy ± min. [°F] | 4.5 | |
Accuracy Max. [%] | 1 | |
Integrated temperature probe [°C] | ||
Min. measuring range | Integrated temperature probe [°C] | ||
Max. measuring range | Integrated temperature probe [°C] | ||
Accuracy ± min. [°C] | ||
Accuracy ± Max. [°C] | ||
Integrated temperature probe [°F] | ||
Min. measuring range | Integrated temperature probe [°F] | ||
Max. measuring range | Integrated temperature probe [°F] | ||
Accuracy ± < 23 °F to 150 °F °F [°F] | ||
Accuracy ± > 150 °F [°F] | ||
Dew point temperature [°C] | ||
Min. measuring range | Dew point temperature [°C] | ||
Max. measuring range | Dew point temperature [°C] | ||
Accuracy | ||
Humidity | ||
Min. measuring range | Humidity [%] | ||
Max. measuring range | Humidity [%] | ||
Accuracy [%] | Humidity | ||
Ambient conditions | ||
Operation - min. temperature [°C] | 0 | |
Operation - max. temperature [°C] | 50 | |
Operation – min. relative humidity [% r.F.] | 10 | |
Operation - max. relative humidity (non-condensing) [%] | 90 | |
Storage - min. temperature [°C] | -10 | |
Storage - max. temperature [°C] | 60 | |
Storage - max. relative humidity (non-condensing) [%] | 80 | |
Display | ||
LCD | ||
Monochrome | ||
Interfaces | ||
USB | ||
Plug connection for type K temperature sensor | ||
Memory organisation | ||
Internal flash memory | ||
Device control | ||
Push buttons | ||
Membrane keyboard | ||
Type of protection | ||
IP54 | ||
IP65 | ||
Temperature sensor | ||
Response time | < 150 ms | |
Spectral sensitivity | 8 ~ 14 µm | |
Laser (target display) | ||
Class | class 2 | |
Wavelength [nm] | 630 ~ 670 | |
Power [mW] | 1 | |
Power supply | ||
Internal (battery) | 9V battery | |
External (USB) | ||
Housing design | ||
Plastics | ||
Dimensions | ||
Length (packaging excluded) [mm] | 122 | |
Width (packaging excluded) [mm] | 49 | |
Height (packaging excluded) [mm] | 160 | |
Weight | ||
(packaging excluded) [kg] | 0.224 |